899
Fitness for
use
Some creep tests
have been conducted in accordance with
ET
AG guideline 001 part 5 and TR 023 in the following
conditions :
in
dry env
ironnement
at 50 °C during 90 days.
 
These tests
show an
excellent behav
iour
of the post-installed connection made with HIT-RE
500-SD:
low
displacements with long term stability,
f
ailure load after exposure
abov
e reference load.
 
 
 
Resistance to chemical substances  
Categories  
Chemical substances
Resistant
Non resistant
Alkaline products
Drilling dust slurry pH = 12,6
+
 
Potassium hydroxide
solution (10%)
pH = 14
+
 
Acids
Acetic acid
(10%)
 
+
Nitric acid (10%)
 
+
Hydrochloric acid
(10%)
 
+
Sulfuric acid (10%)
 
+
Solv
ents
Benz
yl alcohol
 
+
Ethanol
 
+
Ethyl acetate
 
+
Methyl ethyl keton (MEK)
 
+
Trichlor ethylene
 
+
X
ylol (mixture)
+
 
Products from
job s
ite
Conc
rete plasticizer
+
 
Diesel
+
 
Engine oil
+
 
Petrol
+
 
Oil for form
work
+
 
Env
ironnement
Sslt water
+
 
De-mineralised water
+
 
Sulphurous atmosphere (80 cycle
s)  
+
 
 
 
 
Electrical Conductivity  
 
HIT-RE
500-SD
in the hardened
state
is
 not conductive electrically
.
Its electric r
esistiv
ity is 66
 
10
12
:
.m  
(DIN IEC 93 – 12.93).