Hilti HIT-RE 500-SD mortar
w/
rebar (as post-install
ed conn.
)
09
/ 2014
Thes
e pages
are part of the Anchor
Fas
tening
Technology Manual is
s
ue September 2014
899
Fitness for
use
Some creep tests
have been conducted in accordance with
ET
AG guideline 001 part 5 and TR 023 in the following
conditions :
in
dry env
ironnement
at 50 °C during 90 days.
These tests
show an
excellent behav
iour
of the post-installed connection made with HIT-RE
500-SD:
low
displacements with long term stability,
f
ailure load after exposure
abov
e reference load.
Resistance to chemical substances
Categories
Chemical substances
Resistant
Non resistant
Alkaline products
Drilling dust slurry pH = 12,6
+
Potassium hydroxide
solution (10%)
pH = 14
+
Acids
Acetic acid
(10%)
+
Nitric acid (10%)
+
Hydrochloric acid
(10%)
+
Sulfuric acid (10%)
+
Solv
ents
Benz
yl alcohol
+
Ethanol
+
Ethyl acetate
+
Methyl ethyl keton (MEK)
+
Trichlor ethylene
+
X
ylol (mixture)
+
Products from
job s
ite
Conc
rete plasticizer
+
Diesel
+
Engine oil
+
Petrol
+
Oil for form
work
+
Env
ironnement
Sslt water
+
De-mineralised water
+
Sulphurous atmosphere (80 cycle
s)
+
Electrical Conductivity
HIT-RE
500-SD
in the hardened
state
is
not conductive electrically
.
Its electric r
esistiv
ity is 66
10
12
:
.m
(DIN IEC 93 – 12.93).
It is adapted
well
to realize electrically insulating anc
horings
(ex: railway applications,
subway).