1 .. 5 6 7 8 9 10 11 12 13 14 15 16
 
HUS-
V
Screw anc
hor
 
 
 
09
/ 2014
     
     
     
 Thes
e pages
are par
t of
the Anchor
Fas
tening
Technology
Man
ual
is
s
ue
September
2014
 
285
Basic loading
data
for
temporary
application
in
standard and fresh concrete <
28
days old, f
ck,cube
 
 
 
 10
N/
mm²:
 
All data in this
 
s
ection applies to the following conditions:
 
 
x
Strength
class,
f
ck,cube ≥
 10 N/mm²
 
x
Only
temporary
use
 
x
 
Screw is
reusable, before eac
h usage it
must be
checked according Hilti instruction for use with the suited
tube Hilti HRG
 
x
 
Design resistanc
e and recommended
load are v
alid for single anchor only
 
x
 
Design resistanc
e as well as the recommended
load are v
alid for
all load direction and v
alid for both
cracked and non-cracked
concrete
 
x
Minimum
base
material
thickness
 
x
 
No edge distance and spacing influence
 
 
 
Design resistance
Anchor size
HUS-V
8
10
Nominal embedment
depth  
h
nom
 
[mm]
50
65
55
75
Cracked and non-cracked concrete
Tensile N
Rd
= Shear
V
Rd
 
 
 f
ck,cube
 10 N/mm
2
 
[kN]
1,4
 
3,0
 
1,7
 
3,2
 
 f
ck,cube ≥
 15 N/mm
2
 
[kN]
1,7
 
3,7
 
2,1
 
3,9
 
 f
ck,cube ≥
 20 N/mm
2
 
[kN]
2,0
 
4,2
 
2,4
 
4,5
 
 
 
Recommended load
Anchor size
HUS-V
8
10
Nominal embedment
depth  
h
nom
 
[mm]
50
65
55
75
Tensile N
rec
= Shear
V
rec
 
 
 f
ck,cube
 10 N/mm
2
 
[kN]
1,0
 
2,1
 
1,2
 
2,3
 
 f
ck,cube ≥
 15 N/mm
2
 
[kN]
1,2
 
2,6
 
1,5
 
2,8
 
 f
ck,cube
 20 N/mm
2
 
[kN]
1,4
 
3,0
 
1,7
 
3,2
 
a) With ov
erall partial safety factor
for
action
J
 = 1,4. The partial safety factors for action depend on the type of
loading and shall be